Gas Specifications

Model

Gas Type

Gas Control

Min. MJ/h

Input

Max. MJ/h

Input

RFSDV34RFN Natural Radio

Freq.

22

32

RFSDV34RFP

Propane

Radio Freq.

24 32



Gas Inlet and Burner Pressures

Natural

Gas

ULPG

Inlet Minimum

1.1 kPa

2.75 kPa

Inlet Maximum

3.50 kPa

3.50 kPa

Burner Pressure

0.87 kPa

2.50 kPa



Preparation

Warning: The use of wall paper adjacent to this fireplace is not
recommended, as the heat produced by this appliance may adversely
affect the binders in the adhesive used to apply the wall paper.

Before beginning, remove the window frame assembly from the heater and
ensure that there is not hidden damage to the heater.

Take some time to plan the fitting line, flue and electrical supply.

On completion of the installation ensure that the appliance is
commissioned and tested.

Fitting Line Installation

Warning: When purging the fitting line, the front glass must be
removed.

Note:
For pipe sizing requirements refer to Australian Standard AS5601
Gas Installations.

If gas fitting line has been previously completed, check that the gas fitting
line is of adequate size. Refer to Australian Standard AS5601 Gas
Installations.

The gas fitting line can be brought in through the rear or the bottom of the
appliance. Openings are provided on the bottom behind the valve to allow
for the gas fitting line installation and testing of any gas connection. It
preferable to bring the fitting line in from the rear right side of the valve as
this allows fan installation or removal without the need to disconnect the
gas fitting line.