Troubleshooting the gas control system, Page 20 of 27 – Raypak RFSDV34RFPAU User Manual

Page 20

Advertising
background image

Troubleshooting the Gas Control System

Comfort Valve System Control Sequence of Operation with Remote

Control

Local Path

On

Path

Auto

Path

Move switch from

manual to remote.

Press any key on

remote control

If the manual switch

is set to remote,

press the mode

button to display ON.

Does the remote

control the main
burner and fan?

Does remote

control change

levels of flame

height, fan speed?

Yes

No

Set levels of flame

height and fan to

“0” to shut off

main burner and

fan

Yes

Turn pilotstat knob

to OFF to turn

valve completely

off

Move switch from

local to remote.

Press any key on

remote control

within 30 seconds

If the setting is

above room

temperature on

the remote control

does the main

valve and fan turn

on?

If the setting is

below room

temperature on

the remote

control, does the

main valve and

fan turn off?

Turn pilotstat knob

to OFF to turn

valve completely

off.

No

No

Five minute

wait period

Set manual switch

to local or remote

Light pilot burner

Did the LED stop

blinking?

Release pilotstat

knob

Turn pilotstat

knob from PILOT

to ON

Cycle switch once and
leave in remote. Press

any key on the Remote

Control for recognition

operation.

Review LED

failure analysis

Move switch from

manual to remote.

Press any key on the

remote control.

Move switch back to

If manual switch is

set to LOCAL, did

main burner light

and fan turn on?

Yes

Turn pilotstat knob to

PILOT to turn off

main burner

Turn pilotstat knob to

OFF to turn valve

completely off.

Choose Manual or

Remote path. Set

switch to manual or

remote.

If the manual switch

is set to remote,

press the mode

button to display

AUTO. Does the

remote control

display the room and

temperature

settings?

Page 20 of 27