Roberts Gorden Vantage TF-Series User Manual

Page 7

Advertising
background image

ROBERTS GOR DON

®

T F-S

E RIE S

S

UB MI TT AL

S

HEE T

© 2004 Roberts-Gordon

APPL ICATION S, ENGI NEE RING AND DET AI LE D GUID ANCE ON SYST EMS DE SIGN, INSTAL LATI ON AND PRODUCT PE RFORMANCE IS AVAI LABLE UPON RE QUEST. ROBERT S GORDON

®

PRODUCT S ARE T O BE

INSTAL LE D ONL Y IN ACCORDANCE WI TH L OCAL L AWS, CODES AND REGUL AT IONS, AND ONLY BY A CONT RACT OR QUALI FIE D I N THE I NST ALL AT ION AND SE RVICE OF GAS-FIRE D HE AT ING EQUI PME NT.

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream
from where the burner and burner tube connect.

Standard Reflector

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

TF-120

6

35

63

35

16

89

161

89

TF-160

6

38

66

38

16

97

168

97

TF-200

6

40

71

40

16

102

181

102

TF-250

6

46

77

46

16

117

196

117

TF-300

6

50

80

50

16

127

204

127

TF-350

8

52

82

52

21

133

209

133

TF-380

8

52

82

52

21

133

209

133

A

C

D

B

One Side Reflector

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

TF-120

6

9

63

47

16

23

161

120

TF-160

6

9

70

54

16

23

178

138

TF-200

6

9

77

59

16

23

196

150

TF-250

6

9

83

65

16

23

211

166

TF-300

6

9

86

69

16

23

219

176

TF-350

8

9

88

73

21

23

224

186

TF-380

8

9

88

73

21

23

224

186

A

C

D

B

Two Side Reflectors

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

TF-120

6

23

66

23

16

59

168

59

TF-160

6

25

72

25

16

64

183

64

TF-200

6

27

78

27

16

69

199

69

TF-250

6

32

84

32

16

82

214

82

TF-300

6

35

88

35

16

89

224

89

TF-350

8

40

91

40

21

102

232

102

TF-380

8

40

91

40

21

102

232

102

A

C

D

B

Advertising