Installation, Optional remote control, Final check – Regency Wraps F38-LPG2 User Manual

Page 12: Optional wall thermostat

Advertising
background image

12

Regency F38-2 Freestanding Gas Stove

OPTIONAL REMOTE

CONTROL

Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location, use Thermostat Wire Table.

2) Connect the wires as per the wiring diagram

above.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the cor-

rect fi ring rate (rate noted on label) at 15
minutes.

2) If required, adjusting the primary air to

ensure that the fl ame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that
causes sooting or carboning that

results in damage to the exterior

facia is not the responsibility of the

CAUTION

Do not connect the millivolt

remote control wires to

the 240V wires.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

INSTALLATION

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

15.24 m
9.75 m
6.10 m
3.66 m
2.71 m

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:

Note: Preferable if the thermostat is installed
on an interior wall.

Regency offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 240 V wires.