Maintenance, Fan maintenance, Replacing f38-2 fan – Regency Wraps F38-LPG2 User Manual

Page 18

Advertising
background image

18

Regency F38-2 Freestanding Gas Stove

MAINTENANCE

FAN MAINTENANCE

If your fan requires maintenance or replacement,
access to the fan is through the access panel
on the rear wall of the fi rebox.

If the unit is damaged or needs repair, it shall
be repaired by the manufacturer or its service
agent or similiarly qualifed person in order to
avoid a hazard.

Note: The unit MUST NOT be operated

without the fan access panel securely
in place and correctly sealed.

IMPORTANT

Disconnect power supply

before servicing

IMPORTANT: These fans collect a lot of
dust from within your home. Ensure you
maintain these fan motors on a regular
basis by vacuuming out the fan squirrel
cages, around the motor, and around the
grills on the back of the stove.

Diagram 2

4) Lift fan off of the 2 pins, tip back and pull

through fi rebox opening. Disconnect the
green ground wire from the left side of the
fan as soon as you can reach it.

Diagram 1

WARNING: Electrical Grounding In-
structions This appliance is equipped
with a three pronged (grounding) plug
for your protection against shock haz-
ard and should be plugged directly
into a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.

To Remove F38-2 Fan:

1) Unplug or disconnect power source to

stove.

2) Remove all logs and the rear log support,

then remove the 10 screws holding the ac-
cess panel in place, see Diagram 1. (Fan
is also accessible by opening the right side
door. See Diagram 2).

3) Unclip the black and white wires from the

fan motor.

Installing Glass:

1) Install both center and side glass onto

aluminium extrusions as per diagram.

2) Place glass assembly into door frame.

3) Install retainers by placing 1 drop of glue

where previously glued and put in place.

4) Install side retainers.

5) Install door catch plate.

6) Install the 24 nuts loosely, do not tighten

yet.

7) Tighten side panels nuts using the following

procedure:

a. tighten top & bottom outside corner nuts

(2)

b. tighten inside nuts (3)

c. tighten top & bottom inside corners (2)


8) Tighten the 10 nuts on center glass re-

tainer.

9) Repeat step 7 for other side panel.

10) Replace new gasket by gluing it in place.

Replacing F38-2 Fan:

Reverse the above steps (1 - 4). If necessary
install a new gasket before replacing the fan
access panel. Make sure the fan wires and the
ground wire are reattached.

Advertising
This manual is related to the following products: