Installation, Clearances to combustibles, Draft diverter – Regency Wraps F38-LPG2 User Manual

Page 6: Flueing, Installation checklist

Advertising
background image

6

Regency F38-2 Freestanding Gas Stove

INSTALLATION

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM
distances. Measure the clearance to both the
appliance and the chimney connector. (The
farthest distance is correct if the two clear-
ances do not coincide.)
For example, if the
appliance is set as indicated in one of the fi gures
but the connector is too close, move the stove
until the correct clearance to the connector is
obtained.

This unit can be installed on a solid combustible
surface like a wood fl oor. This unit can also be
installed directly on carpeting or vinyl when
the bottom pedestal cover plate (provided with
unit) is installed.

This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.

Use the minimum clearances shown in the
diagrams below for all installations.

F38-NG2 & F38-LPG2 Clearances

M i n i m u m c e i l i n g

height is 36" / 914 mm

from top of unit.

If further reduced clear-

ances are needed, ob-

tain requirements for

construction of a pro-

tected wall from your

local building authori-

ties and their allowable

reductions of the listed

clearances.

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit

6" / 155 mm

E Side Wall to Unit

2" / 50 mm

DRAFT DIVERTER

This heater has a draft diverter built in. It must
not be altered, obstructed, or blocked in any way,
and the unit must be installed so that the draft
diverter is in the same atmospheric pressure
zone as the combustion air inlet to the burner.
This heater must be properly connected to a
fl ueing system. This heater is equipped with a
fl ue safety shutoff system.

WARNING: Operation of this heater when
not connected to a properly installed and
maintained fl ueing system or tampering with
the fl ue safety shutoff system can result in
carbon monoxide (CO) poisoning and pos-
sible death
.

FLUEING

This heater is a fl ued appliance and must be
connected to a chimney/fl ue in accordance with
the installation codes.

Note:

The rear pedestal cover plate must
always be fi tted for safety. Electrical
connections inside.

For your safety this heater is equipped with a
fl ue safety switch designed to sense incorrect
fl ueing and react by shutting down the gas sup-
ply. This thermally actuated switch is located
within the draft diverter and will detect either a
blocked chimney or backdraft condition where the
chimney fl ow has reversed. If this switch shuts
the unit down, it indicates a drafting problem that
must be identifi ed and rectifi ed without delay
- the thermally activated switch must never be
bypassed or disconnected as a hazardous or
deadly condition can result.

F38-NG2 & F38-LPG2

Reference Dimensions

C Back Wall to Flue Centerline 10-3/4" / 273 mm

D Side Wall to Flue Centerline 20-1/2" / 520 mm

F Side Wall to Flue Centerline 11" / 280 mm

14) This unit can be installed on a solid combus-

tible surface like a wood fl oor as well as on
carpeting.

INSTALLATION

CHECKLIST

1) Check Clearances to Combustibles. Refer to

the "Clearance to Combustibles" section.

2) Install flueing. Refer to the "Flueing"

section.

3) Make gas connections. Refer to the "Gas

Connection" section.

Test the pilot. Must be as per diagram in the
"Pilot Adjustment" section.

4) If necessary, convert NG to LPG. Refer to

the "Conversion from NG to LPG" section

5) Test Gas Pressure. Refer to the "Gas Pipe

Pressure Testing" section.

6) Install log set. Refer to the "Log Set

Installation" section.

7) Install Front Door. Refer to the "Front Door

Installation" section.

8) Test for fl ue spillage (draft test). Refer to the

"Test for Flue Spillage" section.

9) Install Optional Features. Refer to the

following sections where applicable:

a.

Optional

Wall

Thermostat

b. Optional Remote Control

10) Final check. Refer to the "Final Check"

section.

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi r-
ing correctly and operation fully explained to
customer.

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label) after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning or that results in
damage is not the responsibility of the manu-
facturer.