Maintenance, Maintenance instructions, Log replacement – Regency Wraps F38-LPG2 User Manual

Page 17: Door and glass gasket, Gold-plated doors, Glass replacement

Advertising
background image

Regency F38-2 Freestanding Gas Heater

17

MAINTENANCE

CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE AP-
PLIANCE.

DO NOT USE THIS APPLIANCE
IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL AN
AUTHORIZED SERVICE TECHNI-
CIAN TO INSPECT THE APPLIANCE
AND TO REPLACE ANY PART OF
CONTROL SYSTEM AND ANY GAS
CONTROL WHICH HAS BEEN UN-
DER WATER.

6) Verify proper operation after servicing.

WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION. YOUNG
CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY
ARE IN THE SAME ROOM AS THE
APPLIANCE.

CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERATING
THE APPLIANCE

.

MAINTENANCE

INSTRUCTIONS

1) Always shut the valve off before cleaning.

For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use
a soft clean brush as the logs are fragile
and easily damaged.

2) Clean glass (never when unit is hot), appli-

ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.

The heater is fi nished in a heat resistant
paint and should only be refi nished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.

3) Make a periodic check of burner for proper

position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call an authorized
service person.

4) The appliance and fl ueing system must be

inspected before use, and at least annu-
ally, by an authorized fi eld service person,
to ensure that the fl ow of combustion and
ventilation air is not obstructed.

During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers - do not
block the pilot or burner ports.

5) Keep the area near the appliance clear and

free from combustible materials, gasoline
and other fl ammable

vapours and liquids.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.

Note: Improper positioning of logs may cre-

ate carbon build-up and will alter
the unit’s performance which is not
covered under warranty.

DOOR AND

GLASS GASKET


If the door gasket requires replacement use
7/8" diameter oval door gasket (Part # 650-920).
The glass requires 5/8" fl at glass gasket. See
your Regency dealer.

GOLD-PLATED DOORS

The 24 carat gold plated fi nish on the door
requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the fi nish and will void the
warranty.
Clean any fi ngerprints off before
turning the unit on.

GLASS

REPLACEMENT

Your Regency heater is supplied with high
temperature, 5mm Neoceram silica coated
ceramic glass that will withstand the highest
heat that your unit will produce. In the event
that you break your glass, purchase your re-
placement from an authorized Regency dealer
only, and follow the step-by-step instructions
for replacement.

Removing Glass:

Note: Wearing gloves will protect your

hands while handling glass.

1) Remove the door from the unit and place

on a soft surface to prevent scratching.

2) Pull out the door gasket.

3) Remove the 24 nuts holding the glass

retainers in place. Do not remove the nuts
underneath the retainers.

4) Remove the door catch plate.

5) Remove glass retainers on sides fi rst (3 each

side) then remove two center retainers.

Note: Center glass retainers are glued to

center glass.

6) Remove glass from aluminium extrusions.

When removing center glass, leave white
insulation in place.

Safety Screen: Only required in Australia

Advertising
This manual is related to the following products: