RKP-200/RHB-200

NOTE

: Flashing button illumination provides confir-

mation and error indications during the Learning

and SMART sequence programming. The back-

lighting should be enabled during configuration.

Disabling IR Sensor

An IR sensor on the front of the keypad allows

operation of the system from a handheld remote

control aimed at the keypad. This sensor can be

disabled. Generally, the sensor only needs to be

disabled when two keypads are installed in the

same room. In this case, disable the sensor on the

second keypad to prevent sending IR commands

to both keypads. For the same reason, you might

disable the sensor of a keypad installed near the

components being controlled.
SW9 configures the sensor mode:
To enable the IR sensor, put SW9 in the ON

position.

To disable the IR sensor, put SW9 in the

OFF position.

NOTE

: Learning commands is done by aiming a

handheld remote at the keypad sensor. The sensor

must be enabled during Learning configuration.

Optional Device Buttons

The keypad has four permanent device buttons:

,

, ,

. These device buttons select a

source component for listening and operation.

Pressing a device button makes the normal com-

mands on the other ten buttons available. Device

buttons cannot store normal learned commands;

however, they can store a SMART sequence of

normal commands that is sent when the device

button is pressed.
The RKP-200 provides the option of designating

the and/or the

buttons as additional de-

vice buttons. SW5 configures the button. SW6

configures the

button.

Details of the switch settings are provided with

the instructions for each configuration option, but

here is a summary:
SW1:

Used for invisible layer command

programming for the CD device.

SW2:

Used for invisible layer command

programming for the TUN device.

SW3:

Used for invisible layer command

programming for the AV device.

SW4:

Used for invisible layer command

programming for the MP3 device.

SW5:

In the ON position, enables the but

ton as an additional device key.

SW6:

In the ON position, enables the

button as an additional device key.

SW7:

Enables the learning mode in the ON

position.

SW8:

Enables the SMART programming mode

in the ON position.

SW9:

Enables (ON) or disables (OFF) the IR

sensor on the front of the keypad.

SW10: Enables (ON) or disables (OFF) the

backlighting feature.

Disabling Backlighting

The RKP-200 backlighting feature illuminates a

device button as a reminder of the selected de-

vice as well as the

button when the sound

is muted.
SW10 configures the backlighting mode:
To enable the backlighting, put SW10 in

the ON position.

To disable the backlighting, put SW10 in

the OFF position.