Connecting the system – ROTEL RHB-200 User Manual

Page 8

Advertising
background image

8

RKP-200/RHB-200

+12V DC input

The power connector receives +12V signal when

AC power supply is plugged into a wall outlet.

Clone Input

RJ-45 modular jack accepts CAT-5 cable from

keypad during cloning configuration.

Zone Inputs

Four RJ-45 modular jacks accept CAT-5 cables

from keypads in up to four zones.

Zone IR Outputs

Four 3.5mm mini-jacks send IR signals to the zone

IR inputs on a Rotel receiver.

Common IR Outputs

Six 3.5mm mini-jacks send IR signals to source

components, either to a direct-wired connection

(Rotel components) or to an IR emitter.

Connecting the system

Master keypads in up to four remote zones con-

nect to a centrally-located RHB-200 Connecting

Hub using standard Category 5 Ethernet-style ca-

bling and 8-pin RJ-45 modular plugs. A second

keypad can be added in each of the four zones,

if desired. The second keypad is connected to the

master keypad in its zone and provides duplicate

functions from a second location.

Cable selection

Run 8-conductor CAT-5 Ethernet cabling from each

keypad location to the RHB-200 Connecting Hub.

Terminate each end of the cables with standard 8-

pin RJ-45 modular plugs. Use a “straight-through”

wiring code, with the same color wire connected

to the same pin on every plug as shown below. If

your cable has different color codes, make sure to

wire every modular plug in the same order.

1

2

3

4

5

6

7

8

GREEN STRIPE

GREEN SOLID

ORANGE STRIPE

BLUE SOLID

BLUE STRIPE

ORANGE SOLID

BROWN STRIPE

BROWN SOLID

This illustration shows the signals carried by each

conductor of the CAT-5 wiring:

1

2

3

4

5

6

7

8

RX

TX

comm. data

A1

B1

IR +

IR

GND

+12VDC

comm. control

infrared signals

power

Connecting Master Keypads

See Figure 3
The first keypad in each zone is designated as the

master keypad. All master keypads connect directly

to the RHB-200 Connecting Hub as follows.
1. For Zone 1, connect one end of the cable to

the ZONE OUT modular jack on the back of

the master keypad.

2. Connect the other end to the ZONE 1 modular

jack on the RHB-200 Connecting Hub.

3. Repeat for the master keypads in Zones 2, 3,

and 4, using the ZONE 2, ZONE 3, and ZONE

4 modular jacks on the RHB-200.

The master keypads are shown in normal shading

on the illustration.

Connecting a Second Keypad

See Figure 3
An optional second keypad in each zone is des-

ignated as a slave keypad. Slave keypads always

connect to the master keypad in the zone:
1. Connect one end of a Category 5 Ethernet

cable from the ZONE OUT modular jack on

the slave keypad.

2. Connect the other end to the ZONE IN jack

on the master keypad.

3. Repeat for the master keypads in Zones 2, 3,

and 4, using the ZONE 2, ZONE 3, and ZONE

4 modular jacks on the RHB-200.

Optional slave keypads are shown in lighter shad-

ing on the illustration.