16

RKP-200/RHB-200

Programming a SMART Sequence

with

Invisible Layer Commands

To include invisible layer commands in a SMART

sequence, substitute the following steps for Step

4 in the preceding instructions:
• Put SW1, SW2, SW3, or SW4 in the ON posi-

tion to select the invisible layer where the de-

sired command is stored:

• Press the invisible layer command button.
• Return the SW1 – SW4 switch to the OFF po-

sition to exit invisible layer mode.

Cloning

Once you have completed the learning and

SMART sequence programming for one keypad,

it is easy to transfer that programming to all of the

keypads connected to the RHB-200 with a proce-

dure called cloning.
To clone a keypad:
1. With the RHB-200 disconnected from the AC

wall power, connect the ZONE OUT connec-

tor of the programmed keypad to the CLONE

IN modular jack on the back of the RHB-200

using a CAT 5 cable.

2. Make sure that all keypads to be programmed

are connected properly as shown in Figure 5.

You can program two keypads in a single zone

as shown by light shaded keypads in the illus-

tration.

NOTE

: Keypads in the remote zones must not be in

Learning or SMART configuration mode.
3. Power on the RHB-200 by connecting it to the

AC power source. The four Zone LEDs on the

front of the RHB-200 flash green once. The

LED on the keypad being cloned flashes

once.

4. Press the large CLONE button on the front

panel of the RHB-200. The cloning process

begins in sequence, starting with the first key-

pad in ZONE 1. While this keypad is receiv-

ing cloned data, the ZONE 1 LED on the front

of the RHB-200 flashes red. When the cloning

of the first keypad is complete, the LED glows

solid red. The cloning process then continues

to the second keypad in ZONE 1 (if it exists).

The LED flashes green during the cloning and

glows solid green when the cloning is com-

plete.

5. Step 5 is then repeated automatically for Zone

2, Zone 3, and Zone 4 as necessary. The entire

cloning process can take up to 10 minutes.

6. If an error occurs, all four LEDs on the RHB-200

flash green six times and the DEVICE buttons on

the zone keypads flash on for one second.

Resetting keypads

Should you want to reset a keypad to its original

factory programming, use a small pointed ob-

ject to press the reset button on the side of the

keypad. This erases all learned commands and

SMART sequences.

Changing buttons

A selection of replacement buttons is available from

Rotel to customize keypads. To replace buttons:
1. Press the two tabs at the top and bottom of the

keypad and pull the keypad module from the

mounting bracket:

Advertising