Table 6-2 . serial commands, Pre l iminar y – Runco QUANTUM COLOR Q-750I User Manual

Page 93

Advertising
background image

Serial Communications

Q-750i Series Installation/Operation Manual

77

PRE

L

IMINAR

Y

Input:

op sharp.mode = 1 [CR]

Response:

OP SHARP.MODE = 1 [CR]

Input:

op sharp.simple = 50 [CR]

Response:

OP SHARP.SIMPLE = NA [CR]

Input:

op sharp.simple ? [CR]

Response:

OP SHARP.SIMPLE = NA [CR]

The last three commands show what happens when a control is grayed out. In this case,
the sharpness mode was set to advanced (value = 1) and then the simple sharpness slider
was attempted to be adjusted and queried. The response was “NA” or not available.

Table 6-2. Serial Commands

Operation

Commands

Values

Notes

aspect

= ?

0 = 16:9
1 = Letterbox
2 = 4:3
3 = VirtualWide
4 = Cinema
5 = VirtualCinema

memory

= ?

0 = Custom 1
1 = Custom 2
2 = ISF Day
3 = ISF Night
4 = Default

? returns a value only if
ISF Day or ISF Night is
active, otherwise it returns
NA.

save.mem

=

0 = Custom 1
1 = Custom 2

save.isf

=

0 = ISF Day
1 = ISF Night

bright
contrast
saturat
tint
sharp
nr

= ? + -

0 - 200

overscan

= ?

0 = Off
1 = Crop
2 = Zoom

source.sel

= ?

0 = HDMI 1
1 = HDMI 2
2 = RGB
3 = Component 1
4 = Component 2
5 = S-Video
6 = Video
7 = SCART

Advertising