Level setting the blt, 1khz test tone @ “0db – Rockford Fosgate 500.2 User Manual

Page 23

Advertising
background image

– 20 –

Level Setting the BLT

Disconnect Speaker(s) from the amplifier

CD Software used to set levels is a test tone of 1kHz at “0dB” or “All Bits High”

Source Unit set to 3/4 volume (or maximum unclipped output)

Remove BLT Cover to access

test pads and gain pots

AC Voltmeter set to

AC Volts

AC Voltmeter “–” connected to

RCA shield of BLT

AC Voltmeter “+” connected to

test pad inside the BLT

Adjust BLT Gain from

3.25 VRMS min. to 10.3 VRMS max per test pad (see chart below)

Be sure the time index reads greater than 30 seconds on source unit.

*Absence of gain overlap will reduce SPL and may not permit amplifier to reach full output power due to various CD
software.

Gain Overlap

BLT Output (AC Volts)

Performance Characteristics

+0dB*

3.25 VRMS

Best S/N Ratio, Reduced SPL

+5dB

5.8 VRMS

Good S/N Ratio & SPL

+10dB

10.3 VRMS

Best Compromise between S/N Ratio & SPL