Electrical Supply Connection

Your refrigerator is intended as a permanent

installation.

Connect the appliance to the electrical supply (220–240 V ~

50 Hz) with the plug and lead, which are fitted.
Connections to the mains supply should be in accordance

with local regulations.

WarnInG: tHIs aPPlIance MUst Be eartHeD

All external wiring must comply with the IEE Regulations

for the Electrical Equipment of Buildings. The appliance is

supplied with a 3-core cable 2 m long. If a replacement cable

is fitted it must be 250 V high temperature PVC (85 °C), 1 mm².
Should the plug not fit the socket in your home, it should be

removed and replaced with a suitable plug.
note: If the plug is fitted is not suitable, it must be cut off and

disposed of properly. To avoid the risk of electrocution, the

plug must not be left where children might find it and plug it

into a supply socket.
Three pin plugs to BS 1363 with a capacity of not less than

13 A must be used and fitted with a 13 amp fuse ‘ASTA’

approved to BS 1362.
You MUST refit the cover after replacing the fuse. If the cover

is lost, the plug MUST NOT be used until a replacement cover

has been obtained from your supplier. The colour of the

correct fuse carrier is that of the coloured insert in the base of

the fuse recess, or stated elsewhere on the plug. Always state

this colour when ordering a replacement fuse carrier.
IMPortant: The wires in the mains lead are coloured in

accordance with the following code (fig.4-14):

Green and yellow:

EARTH

Blue:

NEUTRAL

Brown:

LIVE

Earth: to the

terminal marked E,

coloured Green/Yellow

Live: to the

terminal marked L,

coloured Brown

Neutral: to the

terminal marked N,

coloured Blue

fig.4-14