Chapter 2. Installation

ARC-101 Installation & Operation Manual

2-10

ARC-101 Modules

E1 and E1/LTU
Modules

The E1 link interface (Coax/UTP), as well as RX/TX ground reference, can be
determined by jumpers on the module (see Figure 2-16).

Figure 2-15 E1 Module Front Panel

Connector:

BNC (RJ-45)

Used with:

Coax (UTP)

Protocols supported:

E1

Coding method:

HDB3

Impedance:

75

(120

)

Receive level (with LTU):

0 to -34 dB

Receive level (without LTU):

0 to -12 dB

Transmit level balanced:

3v

±

10%

Transmit level unbalanced:

2.37v

±

10%