ARC-101 Installation & Operation Manual

Chapter 4. Software Management

Performance Monitoring Window

4-7

Link Status

ATM Status

PERFORMANCE MONITORING

1. Link Status

2. ATM Status

3. Reset Counters

ESC. Exit

Link Status

The Link Status window displays:

The number of alarms and errors detected in the last second ("Last
Second" column).

The number of errors detected since the last counter reset or overflow
("All" column).

The time (in seconds) since the last counter reset.

Link Status

STS-3C (FIBER)

Last Second

ALL

T3 (Coax)

Last Second

ALL

LOS

0

0

LOS

0

0

LOF

0

0

OOF

0

0

LOP

LOC

0

0

AIS

0

0

SLM

0

0

Yellow

0

0

Line AIS

0

0

BIP

0

0

Path AIS

0

0

FEBE

0

0

Line FERF/RDI

0

0

P1/P2

0

0

Path FERF/RDI

0

0

Section BIP

0

0

PLCP LOF

0

0

Line BIP

0

0

PLCP YELLOW

0

0

Path BIP

0

0

Line FEBE

0

0

PLCP BIP

0

0

Path FEBE

0

0

PLCP FEBE

0

0

Example: Link Status window for ARC-101 in SONET-T3 configuration