(2) Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 1)

Figure 3.12 shows how to connect the emulation probe to a 100-pin 0.65-mm-pitch foot pattern on
the target system with the M3T-DUMMY100S (not included), and here following is its procedure.
For details on the M3T-100LCC-DMS and M3T-DUMMY100S, refer to each user's manual.

(1) Attach the M3T-DUMMY100S to the target system.

For details on how to attach the M3T-DUMMY100S to the target system, see the user's
manual of the M3T-DUMMY100S.

(2) Attach the M3T-100LCC-DMS to the M3T-DUMMY100S.
(3) Attach the M30800T-PTC to the M30850T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

Figure 3.12 Connecting to a 100-pin 0.65-mm-pitch foot pattern (1/3)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulator.

• The small connectors of the M3T-100LCC-DMS and M3T-DUMMY100S are

guaranteed for only 20 insertion/removal iterations.

• The small connectors of the M30800T-PTC are guaranteed for only 50 insertion/

removal iterations.