(6) Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 2)

Figure 3.16 shows how to connect the emulation probe to a 100-pin 0.5-mm-pitch foot pattern on the
target system with the M3T-FLX-100NSD (not included), and here following is its procedure. For
details on the M3T-100LCC-DMS and M3T-FLX-100NSD, refer to each user's manual.

(1) Attach the M3T-FLX-100NSD to the target system.

For details on how to attach the M3T-FLX-100NSD to the target system, see the user's manual
of the M3T-FLX-100NSD.

(2) Attach the M3T-100LCC-DMS to the M3T-FLX-100NSD.
(3) Attach the M30800T-PTC to the M30850T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

Figure 3.16 Connecting to a 100-pin 0.5-mm-pitch foot pattern (2/3)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulator.

• The small connectors of the M3T-100LCC-DMS and M3T-FLX-100NSD are

guaranteed for only 20 insertion/removal iterations.

• The small connectors of the M30800T-PTC are guaranteed for only 50 insertion/

removal iterations.