Camera opeartional modes – Ricoh GigE Vision VGA Monochrome CCD Camera FV-G200B1 User Manual

Page 11

Advertising
background image



11/38

FV-G200B1
User’s Guide Rev. 1.02

3. Camera Opeartional Modes

3.1

Normal Mode

3.2

Pulse Width Trigger Mode

In this trigger mode with positive polarity, the camera exposure starts at the rising edge of the trigger pulse and

stops at the falling edge of the trigger pulse. Therefore, if positive polarity exposure is selected, the exposure periods
are the high states of the trigger pulse.

3.2.1

Timing

Note 1: The video output is going to be V reset by the next internal HD signal immediately after the exposure is finished.

The exposure time is set by the pulse width of the trigger signal.

Note 2: The FVAL signal does not output when the exposure by the trigger signal does not exist.

Ex p o s u r e

t i me

I n t e r n a l VD

CCD

e x p o s u r e

Vi d e o o u t

Exposure

time

Max. 1H

Internal VD

CCD exposure

Trigger signal

(Positive)

Video out

*Note. 1

*Note. 2

FVAL

Advertising