FV-G200B1
User’s Guide Rev. 1.02



Command No.

Command Description

19H

FORMAT[7..0]

[Image output format] initial data: FORMAT[7..0] = 01H

Sets the output format of the image data.

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

D7 to D3:

No Function

Always set as “00000”

D2 to D0:

Output format

000: Mono8 (Monochrome)

/ BayerRGB8 (Color)

001: Mono10 (Monochrome)

/ BayerRGB10 (Color)

010: Mono10Packed (Monochrome)

/ BayerRGB12 (Color)

011: Mono12 (Monochrome)

/ BayerRGB10Packed (Color)

100: Mono12Packed (Monochrome)

/ BayerRGB12Packed (Color)

101: No function (Do not set)

/ BayerRGB8Packed (Color)

100 to 111: No function (Prohibited setting. Do not set these values)

20H:

EXPTM[7..0]

21H:

EXPTM[15..8]

22H:

EXPTM[23..16]

[Exposure time (useconds) of the electronic shutter]

Initial data: EXPTM[23..0] = 0, data range: 0 to 16,777,215

Sets the exposure time for the electronic shutter.

Exposure time = EXPTM[23..0] useconds

When set as 0, the electronic shutter is OFF.

30H:

PGA[7..0]

[CDS gain] Initial data: PGA [7..0] = 0, data range: 0 to 255

Sets the CDS gain (programmable gain)

CDS gain = 8.72 + 0.04 x (PGA[7..0] x 2 + GOFS[7..0])dB

*GOFS[7..0]:

The gain offset (The value of the address 32H)

31H:

DGB[7..0]

[Digital gain] Initial data: DGB [7..0] = The factory adjusted value

Video level = (Input video level – CLAMP level) x (1 + DGB[7..0]/128) + CLAMP Level

*CLAMP Level

Clamp level (The calculated value of the address 38H)

32H:

GOFS[7..0]

[Gain offset] Initial data: GOFS[7..0] = The factory adjusted value, data range: 0 to 255

38H:

CLAMP[7..0]

[Clamp level] Initial data: CLAMP[7..0] = 9; data range: 0 to 31

Sets the clamp level (The clamp level of the black signal)

Clamp level = CLAMP[7..0] x 8 + 56

(for 12bit output)

Clamp level = (CLAMP[7..0] x 8 + 56) / 4

(for 10bit output)

Clamp level = (CLAMP[7..0] x 8 + 56) / 16

(for 8 bit output)

Whenever it is set greater than 31, it will automatically resets to 31.

Advertising