Status indicators, Switch and port status indicators – Rockwell Tools STRATIX 8000 ETHERNET 1783-MS10T User Manual

Page 15

Advertising
background image

Publication 1783-UM002C-EN-P - April 2009

15

Chapter 1

Status Indicators

The switches and expansion modules have these status indicators.

Switch and Port Status Indicators

VR

T

A

A

31793-M

EIP Mod Status Indicator

EIP Net Status Indicator

Setup Status Indicator

PWR A Status
Indicator

PWR B Status Indicator

Dual-purpose Port
Status Indicator

Port Status Indicator

Indicator

State

Description

EIP Mod
(EtherNet/IP module status)

Off

No power. Check the power supply and cabling.

Solid green

The switch is operating properly.

Flashing

gree

n

The switch has not been configured as a managed switch (for example,
Express Setup was not performed, no IP address, no password). The
switch is operating as an unmanaged switch.

Flashing red

A recoverable minor fault, such as an incorrect configuration, has
occurred.

Solid red

A non-recoverable major fault has occurred. Cycle power. If the
problem persists, contact Rockwell Automation Technical Support.

Flashing green/red

The switch is performing a power-on self-test (POST).

EIP Net
(EtherNet/IP network
status)

Off

No power or no IP address.

• Check the power supply and cabling.
• Make sure switch is properly configured.

Solid green

The device has at least one established EtherNet/IP connection.

Flashing

gree

n

No EtherNet/IP connection yet, but the switch has obtained an IP
address.

Flashing red

EtherNet/IP connection has timed out.

Solid red

Duplicate IP address. The switch has detected that its IP address is
already in use.

Flashing green/red

The switch is performing a power-on self-test (POST).