Mount the switch, To the – Rockwell Tools STRATIX 8000 ETHERNET 1783-MS10T User Manual

Page 32

Advertising
background image

32

Publication 1783-UM002C-EN-P - April 2009

Chapter 2

4.

Push the upper and lower module latches in to secure the module to the
switch.

5.

If you are installing a second module, repeat steps 1...4, but secure the
second module to the right side of the first module.

Mount the Switch

You can mount the switch in one of two ways:

• On a DIN rail
• On a wall or panel

Mount the Switch on a DIN Rail

Follow these steps to mount the switch on a DIN rail.

IMPORTANT

You cannot install an expansion module to the right of
1783-MX08F fiber expansion module.

ATTENTION

When mounting the switch on a DIN rail, you can ground the
switch through the DIN rail to chassis ground. Use zinc plated
yellow-chromate steel DIN rail to assist in proper grounding.
The use of other DIN rail materials (for example, aluminum or
plastic)) that can corrode, oxidize, or are poor conductors, can
impede proper grounding. Secure DIN rail to mounting surface
approximately every 200 mm (7.8 in.) using end-anchors
appropriately and using a washer plate along the entire length
of the DIN rail.

31781-M

Advertising