WARNING

This equipment is intended to be grounded. Ensure that the host is connected to earth ground during
normal use.

Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces,
and watches). Metal objects will heat up when connected to power and ground and can cause serious
burns or weld the metal object to the terminals.

Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury and
equipment damage.

An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that
no exposed portion of the DC-input power source wire extends from the power and relay connector.

Ultimate disposal of this product should be handled according to all national laws and regulations.

Do not work on the system or connect or disconnect cables during periods of lightning activity.

Before performing any of the following procedures, ensure that power is removed from the DC circuit.

Read the installation instructions before you connect the system to its power source.

This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than 5A.

This unit is intended for installation in restricted access areas. A restricted access area can be accessed
only through the use of a special tool, lock and key, or other means of security.

A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.

This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or
an electrician if you are uncertain that suitable grounding is available.

This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit.

Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Ultimate disposal of this product should be handled according to all national laws and regulations.

For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection: 10/100/1000
Ethernet

When installing or replacing the unit, the ground connection must always be made first and disconnected
last.

To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of 167 °F (75 °C).

This equipment is supplied as “open type” equipment. It must be mounted within an enclosure that is
suitably designed for those specific environmental conditions that will be present and appropriately
designed to prevent personal injury resulting from accessibility to live parts. The interior of the enclosure
must be accessible only by the use of a tool.

The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards.