4.5 Self-check

(1) Self-check Procedure

To run the emulator self-check, do so as explained here below. While self-checks are in progress,
LEDs will change as shown in Figure 4.5.

(1) Set the switches in the emulation pod same as the factory setting (see "Table 3.1 Switch

settings of the M37760T-RPD-E" on page 24).

(2) When the target system is connected, disconnect the target system.
(3) Within 2 seconds of activating power to the emulator, press the RESET button on the emulator

front panel to switch the emulator to the maintenance mode.

(4) Check the "SAFE" LED starts flashing and then press the RESET button again.
(5) The self-checks will start. If the normal result is displayed in about 2 minutes, the self-check

has terminated normally.

(2) If an Error is Detected in the Self-check

If the self-check does not result normally (ERROR 1 or ERROR 2 in Figure 4.5), check the following.

• Check the connection of the emulation pod and the PC4701.
• Redownload the proper firmware.
• Check if the switches in this product is set same as the factory-setting (see "3.2 Switch Settings"

on page 23).

CAUTION

Note on the Self-check:

• If the self-check does not result normally (excluding target system errors), the

emulation pod may be damaged. Contact your local distributor.