Installer – Russound SIX-SOURCE CONTROLLER CAM6.6 User Manual

Page 38

Advertising
background image

38

CAM6.6

12VDC Home Theater Trigger In
This 12VDC Trigger input is used to control
Power Management of the audio sources possibly
being shared with a home theater system. When
the last zone on the CAM6.6 is turned off, 12VDC
presence to the trigger input will prevent the
sources that are on from being turned off. The
connections for the trigger are made using a two-
conductor cable with 1/8” male mini-plug. The tip
is positive (+) and the sleeve is negative (-).

12VDC 100mA Trigger Out
The 12VDC 100mA trigger out can be used to
engage any 12VDC trigger device or component
such as the Russound ACT-1 triggered outlet.
The connections for the trigger out are made
using a two-conductor cable with 1/8” male
mini-plug jacks at each end. The tip is positive
(+) and sleeve is negative (-).

INSTALLER

MAKING CONNECTIONS

12VDC Home Theater Trigger In/Out

Advertising