Rev.1.00, Apr.25.2003, page 27 of 38

Absolute Maximum Ratings

Item

Symbol

Ratings

Unit

Conditions

Supply voltage

VDD

–0.5 to 4.6

V

Input voltage

V

I

–0.5 to 4.6

V

Output voltage *1

V

O

–0.5 to VDD
+0.5

V

Input clamp current

I

IK

–50

mA

V

I

< 0

Output clamp current

I

OK

–50

mA

V

O

< 0

Continuous output current

I

O

±50

mA

V

O

= 0 to VDD

Maximum power dissipation
at Ta = 55°C (in still air)

0.7

W

Storage temperature

Tstg

–65 to +150

°C

Notes:

Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage
to the device. These are stress ratings only, and functional operation of the device at these or
any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute maximum rated conditions for extended periods may affect device
reliability.

1. The input and output negative voltage ratings may be exceeded if the input and output clamp

current ratings are observed.

Recommended Operating Conditions

Item

Symbol

Min

Typ

Max

Unit

Conditions

Supply voltage

VDD

3.135

3.3

3.465

V

Supply voltage

VDDA

3.135

3.3

3.465

V

DC input signal voltage

–0.3

VDD+0.3

V

High level input voltage

V

IH

2.0

VDD+0.3

V

Low level input voltage

V

IL

–0.3

0.8

V

Operating temperature

T

a

0

70

°C