Intake Lines
Pressurized Freshwater Models
Install a shut off valve in intake line before water
solenoid valve.
1. Connect hose from pressurized freshwater

source to a shut off valve.

2. Connect hose from shut off valve to inlet port

of water solenoid valve.

NOTE: To avoid malfunction of water solenoid

due to debris in water, installation of Freshwater
Strainer (FWSC*) is recommended.

3. Connect hose from outlet port of water solenoid

valve to inlet port of vacuum breaker.

4. Connect hose from outlet port of vacuum

breaker to toilet bowl.

Sea Water Models
Intake pump fittings are interchangeable to allow
more flexibility during installation. There are two
inlet ports on either side of the intake pump. The
outlet port (to toilet bowl) is at the top of the intake
pump (Arrow).
1. Slide fitting clips back.
2. Select inlet port to be used.
3. Install the appropriate fittings into inlet and

outlet ports used.

4. Install the plug fitting into unused inlet port.
IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage will occur!
5. Reinstall fitting clips.
NOTE: The 90° fitting can be rotated 360°.

6. Connect hose from seacock to inlet port of

In-Line Strainer.

7. Connect hose from outlet port of In-Line

Strainer to inlet port of intake pump.

IMPORTANT: Double clamp all below
waterline hose connections!
8. Connect hose from outlet port of intake

pump to bowl elbow located on back of toilet
bowl.

From

Seacock

To Intake

Pump

Inlet Ports

Outlet Port

Arrow

From Pressurized

Freshwater Source

(Shut Off Valve)

To Inlet Port of

Vacuum Breaker

OUT

IN

11

INSTALLATION

Outlet Port

Inlet Port