Installation – Raritan Engineering Crown Head II User Manual

Page 7

Advertising
background image

SPECIFICATIONS

Base Depth:

10 7/8"

(27.6cm)

Height:
17 3/8"

(44.1cm)

Household

17" (43.2cm)

Marine

Base Width:

10 1/2"

(26.8cm)

Bowl Width:

14 3/8" (36.6cm) Household

13" (33cm) Marine

Bowl Depth:

19 1/4" (48.9cm) Household

16 3/4" (42.6cm) Marine

Plumbing

Maximum suction of Intake pump
(Maximum height above waterline) 4 Ft. (1.2m) from Intake Pump

Maximum height of discharge
vented loop

6 Ft. (1.8m) from base of toilet

INSTALLATION

Recommended Wire and Breaker Sizes for Crown Head II with Diaphragm Intake Pump

Units

Voltage
12V DC
24V DC
32V DC

Main Circuit

Breaker/Fuse Amps

40
20
15

Discharge Pump

Assembly Amps

18

9
7

Recommended Wire and Breaker Sizes for Crown Head II with Pressurized Freshwater

Diaphragm Intake

Pump Amps

10

5
4

Units

Voltage
12V DC
24V DC
32V DC

Main Circuit

Breaker/Fuse Amps

25
15
10

Distance (feet) and Wire (AWG)

Discharge Pump

Assembly Amps

18

9
7

Water Solenoid

Valve Amps

1

.5
.5

10' 15' 20' 25' 30' 40' 50'
10

10

8

8

6

6

4

16

16 14 12 12 10 10

16

16 16 14 14 12 12

Branch Circuit Wire to Water Solenoid Valve: use 16 AWG Wire

Wire Sizes Conversion Table

16

14

12

10

8

6

4

2

1.5

2.5

4.0

6.0

10.0 16.0 25.0 35.0

AWG

mm

2

7

NOTES: for Wire Sizes
1. Distances are from source (battery) to unit and back to source (battery).
2. Recommended conductor wire minimum AWG (mm

2

) for 3% voltage drop.

3. Recommended conductor sizes are based on 105°C rated insulation.

Refer to ABYC Standards for other insulation ratings.

10' 15' 20' 25' 30' 40' 50'
10

8

6

6

4

4

2

16

14 12 12 10 10 8

16

16 16 16 16 16 14

Distance (feet) and Wire (AWG)

Pressurized water source must provide a minimum flow rate of 3 gallons
(11.3 liters) per minute at a minimum pressure of 5 psi (34.5 kPa).

Feet to Meter Conversion Table

10

15

20

25

30

40

50

3.1

4.6

6.1

7.2

9.2

12.2 15.2

Feet
Meter