Installation – Raritan Engineering Crown Head II User Manual

Page 9

Advertising
background image

Mounting Atmospheric Vacuum Breaker

(Pressurized Freshwater Model only)

1. Install fittings as shown.
2. Locate mounting area that is a minimum of

6" (15.3cm) above toilet.

3. Secure where top is in horizontal position.

Mounting In-Line Strainer

(Seawater Models Only)

Make sure strainer bowl is tight.
1. Locate strainer where it will be accessible.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Install fittings provided (#PLA14) on strainer’s

inlet and outlet ports.

4. Mount strainer. Strainer must be mounted

according to flow markings on strainer body.

Mounting Remote Intake Pump

(Sea Models Only)

1. Locate on a flat solid surface in an area that is

dry and well ventilated.

NOTE: Location should not be greater than 48"
(122cm) above the waterline.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Mount pump. Do not over tighten bolts.

Installing Lower Cover
1. Slide cover over lower unit.
2. Secure in place with plastic beaded tie.
NOTE: Do not install until installation is
completed.

INSTALLATION

Flow Marking

6"

(15.3cm)

9