12. Parallel Interface

The two-way parallel interface is compatible with the IEEE compatibility mode and nibble

mode. Refer to the separate Specifications Manual for details.

Table of Connection Signals for Each Mode

Pin No.

Direction

Compatibility Mode

Signal Name

Nibble Mode

Signal Name



In

nStrobe

Host Clock



In/Out

Data0

Data0



In/Out

Data

Data



In/Out

Data

Data



In/Out

Data

Data

6

In/Out

Data

Data



In/Out

Data

Data



In/Out

Data6

Data6



In/Out

Data

Data

0

Out

nAck

PtrClk



Out

Busy

PtrBusy/Data,



Out

PError

AckDataReq/Data,6



Out

Select

Xflag/Data1,5



HostBusy



6

Signal GND

Signal GND



Frame GND

Flame GND



OUT

+ V

+ V

~0

Twisted Pair Return

Twisted Pair Return



In

nInit

nInit



Out

nFault

nDataAvail/Data0,



External GND





6

In

nSelectIn

Active

Parallel interface connector (printer side)

This connector mates with an
Amphenol 57-30360 connector