Modes of operation, Supply voltage – Omega Vehicle Security DRA-DCC-8 User Manual

Page 5

Advertising
background image

3

The DRA-DCC-8 is powered by a DC power supply at a range of 15-32Vdc. In order
to determine the minimum supply voltage, use the following equation:

Vmin = 8 + Rload(

) * 0.02

where:
Vmin is the minimum required supply voltage.
Rload(

) is the maximum output load including the leads resistance.

Note: If Vmin turns to be less than 15V, the minimum required voltage

should be 15 Vdc.

5. MODES OF OPERATION

The DRA-DCC-8 unit can be operated in several modes, determined by an internal
array of 8 DIP switches as follows:

4-20 or 0-20mA output current mode
Parallel control mode
Serial control mode
Self test mode

5.1 0-20 OR 4-20mA OUTPUT CURRENT MODE

Two current output spans are available: 4-20mA or 0-20mA selected by SW6.
The DRA-DCC-8 receives 12 bits of data which determine the output current value.
A channel data value of 4095 (FFF) is always interpreted as a 20mA output current.
A channel data value of 0 (000) will produce a 0mA output current when SW6
is OFF, or 4mA when ON.

5.2 SWITCH SETTINGS

Parallel Control Mode

S1

S2

S3

S4

S5

S6

S7

0-20mA
4-20mA

OFF

OFF

OFF

OFF

X

X

X

OFF

OFF

ON

OFF

X

X

X

MODE