6. PARALLEL CONTROL MODE

* according to para #5.2

In the parallel control mode, the DRA-DCC-8 unit is controlled via a 15 bit bus.
Three Address bits (A0-A3) select the proper current output channel and 12 Data
bits (D0-D11) determine its value (A0 and D0 are MSB). The DRA-DCC-8
microprocessor continuously scans the input vector (Address + Data) terminals
and updates its memory tables upon recognizing a new vector. The unit is
asynchronous in nature. The data should be valid for at least 160 microseconds.

S1

S2

S3

S4

S5

S6

S7

SELF TEST#1

ON

OFF

X

OFF

X

OFF

ON

OFF

X

MODE

ON

ON

OFF

X

SELF TEST#2
SELF TEST#3

*

*

S1

S2

S3

S4

S5

S6

S7

PARALLEL MODE

OFF

OFF

*

OFF

X

MODE

6.1 PLC INTERFACE

The PLC's output modules can be divided into
three popular types; TTL output module, 24Vdc
sink type and 24Vdc source type.
There is a jumper selector on printed circuit card
PN 7040 which selects between Sink/Source
input. (TTL output module should usualy be
considered as sink type). See figure 2.

SINK

SOURCE

S1

S2

S3

S4

S5

S6

S7

300

4800

9600

19200

OFF OFF

OFF

OFF

ON

ON

ON

ON

ON
ON
ON
ON

UNIT ID CODE

ON=4-20mA

OFF=0-20mA

BAUD RATE (BPS)

Serial Control Mode