Oceanic Dive Computer Pro Plus 2 User Manual

Page 11

Advertising
background image

11

PSI

10

20

0 5

ATR

FEET

O

2

N

2

Air Time Remaining Bar Graph (ATRBG)
The Air Time Remaining Bar Graph (Fig. 5a) provides a
graphic representation of the time that you can remain at your
present depth and then, following a safe ascent, surface with a
predetermined reserve of breathing gas.

This calculation and display is based on your Breathing Gas
Consumption Rate that is continuously monitored by the Pro
Plus 2, and it takes into account the breathing gas required for
a safe ascent including any required decompression stops.

The green, yellow, and red zones adjacent to the bar graph
enable you to quickly focus on remaining breathing gas times of 60 minutes and less,
based on your pre selected End Pressure Alarm Set Point (described later). The bar
graph is more precise as time decreases toward the red zone.

DIVE TIME REMAINING
The Pro Plus 2 constantly monitors three critical pieces of information; no decompression
status, oxygen accumulation, and breathing gas consumption rate. Refer to the Oceanic
Dive Computer Safety and Reference Manual which describes Dive Time Remaining
which is a display that indicates the time that is more critical for you at that particular
moment (i.e.; whichever time is the least amount available of the three).

Displayed will be either Time Remaining before reaching the No Decompression limit
(Fig. 5b), or Time Remaining before reaching the limit for Oxygen Accumulation, or Time
Remaining before reaching the End Pressure Alarm set point.