Oceanic Dive Computer Pro Plus 2 User Manual

Page 60

Advertising
background image

60

MAX

PSI

10

0 5

DECO

ATR

FEET

O

2

N

2

O

2

Upon ascending above 330 feet (99.9 meters), the Current
Depth display will be restored, however Max Depth will only
display 3 dashes for the remainder of that dive. The Log for
that dive will display 3 dashes as the Max Depth achieved.

Immediate Violation Mode and Gauge Mode

During a Dive, if a ceiling much greater than 60 feet (18
meters) is required, an Immediate Violation Mode will
be entered. This situation would be preceded by entering
Delayed Violation Mode #2.

The Pro Plus 2 would then operate with limited functions in
Gauge Mode during the remainder of that dive and for 24
hours after surfacing. Gauge Mode turns the Pro Plus 2 into
a digital instrument without any decompression or oxygen
monitoring functions.

Only Current Depth, Max Depth, Elapsed Dive Time, and the
bar graphs will be displayed (Fig. 64). The full Tissue Load-
ing Bar Graph and O2 Bar Graph will both flash as a warn-
ing of this condition.

• Press the Left (Advance) button to view Temperature and

Time of Day.

• Press the Right (Select) button to activate the Backlight.

Fig. 64 - Immediate Violation

Gauge Mode (underwater)