Esetting, Imers, Timer modes – Omega Speaker Systems DPS3301 User Manual

Page 18: Imer, Elapsed time, Ow to reset, Lapsed

Advertising
background image


Page

18


To display Timer #1 value, push the TIME key twice. The first push shows elapsed time, while the second
push will first display 'tr1 Cnt' (for Timer1 Count) and then Timer 1 value.

To display Timer #2 value, push TIMER key three times. First two pushes display elapsed time and timer 1
value respectively, while the third push brings up timer 2 value on the display. This is , however, preceded by
the message 'tr2 Cnt' (for Timer 2 Count).

Resetting Timers:


The two Timers can be reset any time and their timing cycle started all over again. To reset Timer 1, push
‘TIMER’ key twice and hold it in. This will bring time left on Timer 1 on the display. While this is being
displayed, simultaneously push the ‘RESET’ key. Timer 1 will reset and its timing cycle will start again
(depending on Timer Mode and Process reading i.e. if it is above Limit 1or below).

Similarly, to reset Timer 2, push ‘TIMER’ key three times and hold it in. This will display remaining time
onTimer2. While this is being displayed, simultaneously push the ‘RESET’ key. Timer 2 will reset and its
timing cycle will start again (depending on Timer Mode and Process reading i.e. if it is above Limit 2 or
below).

TIMER MODES

Timer Mode #0

The timer starts timing from the moment the system is either turned on or the timer is reset. After the
programmed amount of time has elapsed, the respective timer outputs will energize.

Timer Mode #1

When temperature Limit #1 or Limit #2 has been reached, the corresponding timer output (Timer #1 output
for temperature Limit #1 and Timer #2 for temperature Limit #2) will energize and will stay energized for
programmed length of time. After this time has elapsed, the output will de-energize.

Timer Mode #2

The timing for respective timers starts after the temperature Limit #1 or Limit #2 has been reached. For
example, if temperature Limit #1 and Limit #2 are 500 and 1000 degrees respectively and Timer 1 and Timer
2 are programmed for 30 minutes each, then Timer 1 output will come on 30 minutes after the system reads
500 degrees temperature. Similarly Timer 2 output will come on 30 minutes after 1000 degrees temperature
has been reached.

ELAPSED TIME


The system keeps track of process run time since the unit is turned on or the time is last reset. To display
elapsed time, press the ‘TIME’ key. The display will briefly read 'ELPSd t' (for elapsed time), and then
indicate process run time. Display format is HH.MM.SS (HH=hours, MM = minutes, SS = Seconds).
Maximum time that can be displayed is 999 hours 59 minutes and 59seconds.

How to reset Elapsed Time


To reset elapsed time and start timing again, press ‘TIMER’ key once and while keeping it pressed, push
‘RESET’ key. The display will show current elapsed time very briefly, and then reset to 0.


Advertising