3 digital input/output – Omega Vehicle Security DAQ-16 User Manual

Page 15

Advertising
background image

5 6 7 8

1 2 3 4

J4

Channel 1 gain

Channel 1 select

Channel 0 select

Channel 0 gain

Figure 2-5. Jumper J4 Configuration

Table 2-3 lists configuration options for jumper J4.

connect 4-8
open 4-8

connect 2-6
open 2-6

Gain = 1
Gain = 2

connect 3-7
open 3-7

connect 1-5
open 1-5

Bipolar
Unipolar

Channel 1

Channel 0

Table 2-3. Jumper J4 Configuration

When configured for unipolar operation, the output voltage can be calculated from the
equation:

A

= V *

* gain

out

ref

CODE

4096

For bipolar operation, the equation becomes:

A

=

- 1 * V * gain

out

CODE

2048

ref

2.3

Digital Input/Output

The DAQ-16 offers four bits of digital output and four bits of digital input for
control/monitoring of external digital devices. The four digital output lines are LS TTL
compatible and will initialize low (0 volts) on power-up. The four digital inputs are also LS
TTL compatible. There is no termination provided on the digital input lines and a read of an
unused digital input will result in an indeterminate value.

DAQ-16 Users Manual 15

Advertising