Omega Vehicle Security DAQ-16 User Manual

Page 19

Advertising
background image

When configured for a 48-bit divider, the first sampling period will be slightly longer than
the others because the first clock period is required to load the initial value of the
multi-function timer. The following equation calculates the additional time of the first period:

t

= 100ns * [N1 * N2]

add

To minimize the amount of additional time required for the first sample, select clock dividers
such that N1 and N2 are as small as possible and N3 is as large as possible. Using the
equations above, the minimum and maximum data sampling rates and the amount of
additional time required for the first sample can be calculated.

Maximum sampling rate:

Minimum sampling rate:

N1 = 2, N2 = 2, N3 = 25

N1 = 65535, N2 = 65535, N3 = 65535

t = 100 x 10 * [(2)*(2)*(25)]

t = 100 x 10 * [(65535)*(65535)*(65535)]

9

9

t = 100 x 10 * 100

t = 100 x 10 * [2.815 x 10 ]

9

9

14

t = 10 us

t = 28.146 x 10 sec

6

f = 10 x 10 / [(2)*(2)*(25)]

t = 325 days, 18 hours, 23 minutes, 29 sec

6

f = 10 x 10 / 100

f = 10 x 10 / [(65535)*(65535)*(65535 )]

6

6

f = 100 Khz

f = 10 x 10 / [2.815 x 10 ]

6

14

f = 35.529 nHz

t

= 100 x 10 * [2 * 2]

t

= 100 x 10 * [65535 * 65535]

add

9

add

9

t

= 100 x 10 * 4

t

= 100 x 10 * [4.295 x 10 ]

add

9

add

9

9

t

= 400 ns

t

= 429.5 sec

add

add

2.5.2

External Clock

The external clock input to the DAQ-16 is a TTL level (0 - 5 volt) signal. This input may be
used to control the sampling rate directly, or it may be fed through a pre-divider (the
multi-function timer) with the timer output controlling the A/D sampling rate. When used to
control the sampling rate directly, the frequency of the external clock input may be varied
from DC to 100 KHz as long as the width of the low and high portions of the clock are a
minimum of 1 us each. The A/D conversion cycle will begin on each rising edge of the
external clock input. (See Figure 2-7).

10 usec

min

1 usec min 1 usec min

Figure 2-7. Sampling Rate External Clock Pulses