E-146

Symptom

Probable Cause

Action

Playback

Monitor screen contents do
not appear on the screen of
a connected TV.

Cannot access the delete
screen.

Cannot select menu items
in the PLAY mode.

All buttons and switches
are dead.

Nothing appears on the
monitor screen.

1. Incorrect camera-TV connection

2. Wrong TV settings

3. Wrong video signal output mode

All images on the memory card are protected.

1. Some functions cannot be selected for playback

of certain types of images.

2. No images stored on the memory card.

Circuit damage due to static electrical charge from
connected device or due to strong impact.

1. The monitor is asleep.
2. Communication over the USB cable is in

progress.

1. Connect correctly using the video cable (page E-

124).

2. Check the documentation that comes with the

TV and set it up correctly for video input.

3. Select the video output mode that suits the type

of equipment you are using (page E-125).

Unprotect the images you want to delete (page E-
116).

1. Select a different function or change to another

image.

2. Record an image to make the functions avail-

able.

Remove batteries and disconnect the AC adaptor if
you are using one. Restore power and turn the
camera on. If this does not work, contact your
dealer or an authorized CASIO service provider.

1. Wake up the monitor (page E-37).
2. After the communication operation over the USB

cable is complete, unplug the USB cable from
the camera.