Basic problem solving, Intermediate problem solving – Oracom ULTRA MAX 695 User Manual

Page 6

Advertising
background image

6

309067

Basic Problem Solving

TYPE OF
PROBLEM

WHAT TO CHECK
If check is OK, go to next check

WHAT TO DO
When check is not OK, refer to this column

11. Motor thermal cutout switch. Connect ohmmeter between

motor yellow leads. Meter must read 1 ohm maximum.

11. Allow motor to cool. Correct cause of

overheating. If switch remains open after
motor cools, replace motor.

12. Pressure transducer (67) by replacing it with a new one.

12. Replace pressure transducer.

See page 16.

13. Pressure adjustment potentiometer (77) by replacing it

with a new one.

13. Replace potentiometer. See page 14.

Intermediate Problem Solving

TYPE OF
PROBLEM

WHAT TO CHECK
If check is OK, go to next check

WHAT TO DO
When check is not OK refer to this column

Low output

1. For worn spray tip.

1. Follow Pressure Relief Procedure

Warning on page 3, then replace tip.
See your separate gun or tip manual.

2. Verify pump does not continue to stroke when gun trigger

is released. Plug in and turn on sprayer. Prime with paint.
Trigger gun momentarily, then release and engage safety
latch. Relieve pressure, turn off and unplug sprayer.

2. Service pump. See page 11.

3. Release gun trigger. Observe resting position of pump rod

(222).

3. If pump consistently comes to rest

with rod (222) fully extended, the piston
packings and/or piston valve may be
worn. Service pump. See page 11.

4. Electrical supply with volt meter.

Meter must read 90–110 VAC for 232916, 232917.
Meter must read 105–125 VAC for 232910 – 232913,
232919
Meter must read 210–250 VAC for 232918, 232915,
232914.

4. Reset building circuit breaker; replace

building fuse. Repair electrical outlet or
try another outlet.

5. Extension cord size and length; must be at least 12 AWG

(1.5 mm

2

) and no longer than 300 ft (90 m).

5. Replace with a correct, grounded exten-

sion cord.

6. Motor brushes. See Electrical – What To Check, item 4, on

page 5.

6. See page 10.

Low output

(continued)

7. Motor control board (22a) by substituting with a good

board.

CAUTION: Do not perform this check until motor armature
is determined to be good. A bad motor armature can burn
out a good board.

7. Replace board. See page 13.

8. Motor armature for shorts by using an armature tester

(growler) or perform motor test. See page 9.

8. Replace motor. See page 12

.