Motor Test

Relieve pressure; page 3.

For checking armature, motor winding and brush
electrical continuity.

Setup

1.

Unplug sprayer.

2.

Remove drive housing. See page 15. This ensures
that any resistance noticed in armature test is due
to motor and not to worn gears in drive housing.

3.

Fig. 3. Remove brush inspection covers (A).

4.

Fig.4. Remove screws (25, 26). Lower control
board (22a). Disconnect two leads (C) from motor
to board.

A

B

Fig. 3

02991

Armature Short Circuit Test

1.

Remove fan cover (B). See Fig.3.

2.

Spin motor fan by hand. If there are no shorts,
motor coasts two or three revolutions before
coming to complete stop. If motor does not spin
freely, armature is shorted and motor must be
replaced. See page 12.

Armature, Brushes, and Motor Wiring
Open Circuit Test (Continuity)

1.

Fig. 4 Connect red and black motor leads (C)
together with a test lead. Turn motor fan by hand
at about two revolutions per second.

80

green
with yellow
stripe

8386A

Fig. 4

77

67

30

78

C

22a

96

D

E

black

green

white

black

red

yellow

107

108

232910 – 232913, 232916, 232917

232918, 232915, 232919, 232914

77

67

116

78

C

22a

D

E

black

white

black

red

yellow

107

108

8385A

96

119

blue

brown

80

brown

2.

If uneven or no resistance, check for: broken brush
springs, brush leads, motor leads; loose brush
terminal screws or motor lead terminals; worn
brushes. See page 10.

3.

If still uneven or no resistance, replace motor;
page 12.