For technical questions, please call 1-800-444-3353.

SKU 68018

4. To fire, open the shut-off valve, place

the Safety against the workpiece. The

Stapler should not fire if the nose is not

depressed. Once depressed, gently and

briefly squeeze the Trigger once.

Do not

fire repeatedly. Staples could bounce

off of one another, damaging the work

piece or causing PERSONAL INJURY.

5. Adjust position of the Air Deflector (3) to

direct exhaust away from yourself.

6. If the tool requires more force to

accomplish the task, verify that the

tool receives sufficient, unobstructed

airflow (CFM) and increase the pressure

(PSI) output of the regulator up to the

maximum air pressure rating of this tool.

CAUTION! TO PREVENT TOOL AND

ACCESSORY FAILURE, RESULTING

IN INJURY: Do not exceed the tool’s

maximum air pressure rating. If the

tool still does not have sufficient force at

maximum pressure and sufficient airflow,

then a larger tool may be required.

7.

After use, to prevent accidents:

a.

Release the Trigger.

b.

Detach the air supply.

c.

Attempt to fire the Tool into a piece

of scrap wood to ensure that it is

disconnected and is incapable of

firing any fasteners.

d.

Release the Trigger again.

e.

Clean external surfaces with clean,

dry cloth.

f.

Store indoors out of children’s reach.

Advertising