OxiBrands 1/4" 18 Gauge Crown Air Stapler 68018 User Manual

Page 14

Advertising
background image

Page 14

For technical questions, please call 1-800-444-3353.

SKU 68018

3. Hold the Stapler pointed away from you

and any other people or fragile objects

and lift up the Cover Latch (43).

4. Pull up on the Switch, lifting the Cover

Plate (44) up off the Drive Guide (41)

and remove jammed fasteners.

5. Inspect Drive Guide for bends or

breakage. If it is damaged, do not use

tool until it is repaired by a qualified

technician.

6. Lightly oil Drive Guide and replace the

Cover Plate (57).

7. If a fastener is jammed in the Magazine,

unfasten the Latch and slide the Nail

Guide Frame out all the way back. Use

a screwdriver to release the jammed

fastener by probing the openings in the

Guide.

8. Pull out the jammed fastener and the

remainder of the fastener strip that is

still in the magazine. Dispose of the

remaining fastener strip; it may be bent

or damaged in some other way.

9. Reload the Stapler.
10. Reconnect the Stapler to the air hose.
11. Press the Safety Tip against an

appropriate piece of scrap wood and test

fire the Stapler several times, checking

for proper operation.

12. Disconnect Stapler, remove the staples,

and store the Stapler in a location out of

children’s reach.

13. If you are unable to clear the fastener

jam using the method prescribed above,

the tool should be taken to a qualified

service technician for proper servicing.

Advertising