User-maintenance – OxiBrands 1/4" 18 Gauge Crown Air Stapler 68018 User Manual

Page 13

Advertising
background image

Page 13

For technical questions, please call 1-800-444-3353.

SKU 68018

USER-MAINTENANCE

Procedures not specifically

explained in this manual must

be performed only by a

qualified technician.

TO PREVENT

SERIOUS INJURY

FROM ACCIDENTAL OPERATION,

BEFORE ANY MAINTENANCE OR

REPAIRS ARE DONE (including

clearing jams):

• Wear ANSI-approved safety

goggles with side shields. Other

people in the work area must also

wear ANSI-approved impact safety

goggles with side shields.

• Release the Trigger.

• Detach the air supply.

• Attempt to fire the Tool into a

piece of scrap wood to ensure

that it is disconnected and is

incapable of firing any fasteners.

• Empty the staples from the Nail

Guide Frame and Magazine and

leave it open during service.
TO PREVENT SERIOUS INJURY

FROM TOOL FAILURE: Do not

use damaged equipment. If

abnormal noise, vibration, or

leaking air is detected, correct

problem before further use.
TO PREVENT EXPLOSION:

Lubricate only with specified

lubricants. Lubricate the air inlet

using only pneumatic tool oil.

Lubricate the internal mechanism

using only white lithium grease.

Other lubricants may damage the

mechanism and may be highly

flammable, causing an explosion.

Note: These procedures are in addition to

the regular checks and maintenance

explained as part of the regular operation

of the air-operated tool.
Daily - Air Supply Maintenance:

Every day, perform maintenance on the

air supply according to the component

manufacturers’ instructions. The

lubricator’s oil level needs to be

maintained and the moisture filter must

be regularly drained. Performing routine

maintenance on the air supply will allow

the tool to operate more safely and will

also reduce wear on the tool.

Clearing Jams

TO PREVENT

SERIOUS INJURY

FROM ACCIDENTAL OPERATION,

BEFORE ANY MAINTENANCE OR

REPAIRS ARE DONE (including

clearing jams):

• Wear ANSI-approved safety

goggles with side shields. Other

people in the work area must also

wear ANSI-approved impact safety

goggles with side shields.

• Release the Trigger.

• Detach the air supply.

• Attempt to fire the Tool into a

piece of scrap wood to ensure

that it is disconnected and is

incapable of firing any fasteners.

• Empty the Nail Guide Frame and

leave it open during service.

1. If a fastener is jammed in the discharge

area, disconnect tool from air hose,

press down on the Latch and pull back

on Nail Guide Frame.

2. Empty Magazine (49) of staples, release

any built-up air pressure, and leave the

Magazine open.

User-Maintenance Instructions