20 Installation

(for qualified installers only)

© Travis Industries

4090507

100-01217_000

Approved Vent Configurations

Restrictor Position

Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and exhaust

gases. Depending upon the vent configuration, you may be required to adjust the restrictor positions. The

charts for acceptable vent configurations detail the correct vent restrictor positions.

Exhaust Restrictor Adjustment

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust

restrictor is removed.

Loosen these two screws
on the exhaust restrictor.

Slide the restrictor to the correct
restrictor position (see the illustration
below). The screw location indicates
restrictor position. In this example, the
restrictor is set in position # 3. Tighten
the screws to secure the restrictor.

(closed) #6

# 5

# 4
# 3
# 2

(open - stock position) # 1

Left (vent) Side of Firebox

Left Wall of Firebox

Firebox Roof