Location: 26

Dialer Controls: (2

nd

Digit):

2

nd

Digit

Attempts

Answering Machine

UL Installation

Voice Module

0

3

No

No

No

1

8

No

No

No

2

3

Yes

No

No

3

(default)

8

Yes

No

No

4

3

No

Yes

No

5

8

No

Yes

No

6

3

Yes

Yes

No

7

8

Yes

Yes

No

8

3

No

No

Yes

9

8

No

No

Yes

A

3

Yes

No

Yes

B

8

Yes

No

Yes

C

3

No

Yes

Yes

D

8

No

Yes

Yes

E

3

Yes

Yes

Yes

F

8

Yes

Yes

Yes

Central Station Protocols: Location 27-28

Format Name

(PPS)

pulses/sec

Kissoff/

Handshake

Validation

InterDigit

Time

Code

format

Silent Knight/
ADEMCO Slow

10

1400Hz

Dual round

650

0F

Silent Knight/
ADEMCO Slow Extended

10

1400Hz

Dual round

650

4F

Radionics/DCI/ Franklin slow

10

2300 Hz

Dual round

650

17

Silent Knight Fast

20

1400 Hz

Dual round

650

0E

Silent Knight Fast Extended

20

1400 Hz

Dual round

650

4E

Sescoa/Franklin/Vertix/ DCI fast

20

2300Hz

Dual round

650

16

Sescoa/Franklin/Vertix/DCI
Extended

20

2300Hz

Dual round

650

56

Universal high speed

20

2300Hz

Dual round

390

12

Radionics

20

1400 Hz

Dual round

390

02

Radionics

20

2300Hz

Dual round

390

12

Radionics Extended

20

1400 Hz

Dual round

390

42

Radionics Extended

20

2300Hz

Dual round

390

52

Radionics

40

1400 Hz

Dual round

390

00

Radionics

40

2300Hz

Dual round

390

10

Radionics Extended

40

1400 Hz

Dual round

390

40

Radionics Extended

40

2300Hz

Dual round

390

50

Radionics

40

1400 Hz

Parity

390

20

Radionics

40

2300Hz

Parity

390

30

Radionics Extended

40

1400 Hz

Parity

390

60

Radionics Extended

40

2300Hz

Parity

390

70

Example: to use ADEMCO slow enter 0F to location 27