Ensure that all mains operated, ancillary equipment connected to the electric security fence circuit provides

a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the
energizer.
NOTE: Ancillary equipment that complies with the requirements relating to isolation between the fence

circuit and the supply mains in Clauses 14, 16 and 29 of the standard for the electric fence energizer is
considered to provide an adequate level of isolation.

Mains supply wiring shall not be installed in the same conduit as signalling leads associated with the electric
security fence installation.

Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified

by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of
protection IPX4.

Figure 1 – Symbol for warning sign

Warranty

This product is warranted against faulty material and workmanship for a period from the date of
purchase. If a warranted defect occurs, return this product with proof of purchase to the place of
purchase. Details of warranty periods and other terms applying are available at the place of
purchase or at www.tru-test.com.

Note:
- No responsibility is accepted for any accident or damage caused subsequent to any tampering

with or modification to or misuse of this product, including (but not limited to) alterations
made by anyone other than Tru-Test or its agents.

- To the maximum extent permitted by law, this warranty is exclusive, personal to you and in lieu

of all other warranties, representations or conditions relating to this product (whether express
or implied and whenever arising) whether originating by statute, law, trade, custom or
otherwise.

Advertising