Daytime Fence Monitoring

Twenty-four hour fence monitoring can be provided by the unit, even without fully energizing the
fence. During the daytime, when people and children are expected to be around the fenced area,
fence monitoring can be provided at a reduced voltage, by selecting “Monitor mode”. In this
mode the unit is still able to monitor the electric fence installation, and will trigger the alarm if
someone tampers with it.

Entering Monitor mode

Entering Monitor mode using the Keypad

To set Monitor mode, enter the UPIN or OPIN, then press

:

COMMAND

KEY

1

KEY

2

KEY

3

KEY

4

KEY

5

Monitor using:

User PIN

U P I N

or

Owner PIN

O P I N


Note that in Monitor mode the gate is not alarmed, but the Keypad will chime each time the gate
is opened to announce the presence of a visitor or intruder.

Note: This feature cannot be activated using the Keyswitch.

Exiting Monitor mode

Exiting Monitor mode using the Keyswitch

The Keyswitch can be used to exit Monitor mode.
1

Insert the key into the Keyswitch

2

Rotate ¼ turn to the right until a fast beeping is heard.

3

Return the key back to the upright position and remove.