NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Figure 16

Figure 17

Select Venting System - Horizontal or Vertical

With the appliance secured in framing, de-

termine vent routing and identify the exterior

termination location. The following sections

describe vertical (roof) and horizontal (exterior

wall) vent applications. Refer to the section

relating to your installation. A list of approved

venting components is shown on Pages 32

through 34.

Installation of Vent Restrictor

A vent restrictor may be needed with this appliance,

install vent restrictor (provided) in the appliance top

flue outlet as shown in Figure 16 (SSDVT-3328 )

or rear flue outlet as shown in Figure 17 (SSDVR-

3328 ). It is held in place by friction, only.

Step 3. INSTALL THE VENT SYSTEM

General Information

These instructions should be used as a guide-

line and do not supersede local codes in any

way. Install vent according to local codes,

these instructions, the current National Fuel

Gas Code (ANSI-Z223.1) in the USA or the

current standards of CAN/CGA-B149.1 and

-B149.2 in Canada.

Use only approved venting components. See

Approved Vent Components on Page 2.

These fireplaces must be vented directly

to the outside.

The vent system may not service multiple

appliances, and must never be connected to a

flue serving a solid fuel burning appliance. The

vent pipe is tested to be run inside an enclosing

wall (such as a chase). There is no requirement

for inspection openings in the enclosing wall at

any of the joints in the vent pipe.

WARNING

Failure to reinstall and securely

tighten cover plate screws could

result in leakage of flue products

into the living space. Vent cover

plate and vent seal plate must

remain securely installed on

unused vent collar. Failure to do

so could result in leakage of flue

products into living space.

Vent Restrictor Installation

(Top Vent)

A vent restrictor may be needed when verti-

cally terminating the vent system above the roof

(when using the appliance top vent), install vent

restrictor in the top vent of the fireplace outlet on

SSDV-3328 series models. If needed, install the

restrictor orientated as shown, either from inside

or outside the unit,in the inner fireplace collar.

Appliance Top

Vent Outlet

Restrictor

Inner

Fireplace

Collar

VENT RESTRICTOR INSTALLATION

(REAR VENT)

A vent restrictor may be needed when horzon-

tally terminating the vent system from the rear

of the appliance (when using the appliance rear

vent), install vent restrictor in the rear vent of

the fireplace outlet on SSDV-3328 series mod-

els, in any installation that has a vertical vent

run in excess of three feet (0.914 meters).

If needed, install the restrictor orientated as

shown, either from inside or outside the unit,

in the inner fireplace collar

Inner Fireplace

Collar

Appliance Rear

Vent Outlet

Restrictor

Advertising