TOA Electronics SSDV-3328 User Manual

Page 22

Advertising
background image

22

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

H1

V

H

Wall

Firestop/Spacer

(SV4.5HF)

Ceiling

Firestop/Spacer

(SV4.5VF)

When using

Secure Flex, use

Firestop/Spacer

SF4.5HF.

When using

Secure Flex, use

Firestop/Spacer

SF4.5VF.

V

H

H1

Wall Firestop/Spacer

(SV4.5HF)

Wall Firestop/Spacer

(SV4.5HF)

When using Secure Flex,

use Firestop/Spacer

SF4.5HF.

Ceiling

Firestop/Spacer

(SV4.5VF)

Note - When using

Secure Flex, use

Firestop/Spacer SF4.5VF.

Table J

H

+ H

1

Maximum

V Minimum

feet

(meter)

feet

(meter)

3

(0.914)

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

V +

H

+ H

1

= 40 feet (12.2 m) Max.

H

+ H

1

= 20 ft. (6.096 m) Max.

Figure 37

- Rear Vent - TWO 90 DEGREE ELBOWS

Figure 38

- Top Vent - TWO 90 DEGREE ELBOWS

See Table 12 on Page 21 as an aid in venting component

selection for a particular range of exterior wall thick-

nesses.

Square termination (SV4.5HT-2) shown.

Square termination (SV4.5HT-2) shown.

See Table 12 on Page 21 as an aid in venting

component selection for a particular range of

exterior wall thicknesses.

HORIZONTAL VENT FIGURES / TABLES (CONTINUED)

Table H

H

+H

1

Maximum

H

Maximum

V Minimum

feet

(meter)

feet

(meter)

feet

(meter)

5

(1.524)

2

(0.610)

1

(0.305)

10

(3.048)

4

(1.219)

2

(0.610)

15

(4.572)

6

(1.829)

3

(0.914)

20

(6.096)

8

(2.438)

4

(1.219)

V + H + H1 = 40 feet (12.2 m) Max

H = 8 feet (2.438 meters) Max.

H + H1 = 20 feet (6.096 meters) Max.

Example: If 20 feet of (H + H

1

) horizontal vent run is needed,

then 4 feet minimum of (V) vertical vent will be required.
This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V)

vertical, you are allowed 5 feet of (H+ H

1

) horizontal run, up

to a maximum horizontal run of 20 feet.

Example: If 20 feet of (H + H

1

) horizontal vent run is needed,

then 4 feet minimum of (V) vertical vent will be required.

This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V)

vertical, you are allowed 5 feet of (H+ H

1

) horizontal run, up

to a maximum horizontal run of 20 feet.

An elbow is acceptable as 1 foot of vertical rise except where

an elbow is the only vertical component in the system. See

Figure 35.