Preparing the 9110 dms for 326x series card modems – Telenetics Sunrise Series Modular Nest User Manual

Page 26

Advertising
background image

Part No. TEL–09949, Rev A

June 2001

Pre-Installation Information and Activities

Page 26 of 34

Preparing the 9110 DMS for 326X Series Card Modems

When managing 326X Series Modems in an enclosure using the 9110 Dial
Management System (DMS), set the Use option (in the 9110 Comm Port Definition
screen) to Complete. This configures the 9110 to poll all modems (see “Polling” in
Chapter 1 of the 9110 DMS User's Guide) even if one modem is not responding.

Change the Use option to Complete as follows:

1) Shut down the 9110.

2) Start up the Setup Program, log on, and select the Setup File Editor

Option.

3) Open SETUP.WIN from the File menu.

4) Select Edit from the Comm menu. The Comm Port List Window is

displayed.

5) Select a Comm port that is cabled to a 326X Series modem enclosure.

6) Select the Use option and select Complete in the popup window. Ensure

the setting next to Use changes to Complete.

7) Press F1 to save the change in memory.

8) Repeat Steps 4 through 7 for each Comm port cabled to a 326X Series

modem enclosure.

9) Select Save from the File menu and save SETUP.WIN.

10)Exit the Setup Program and restart the 9110.

326X Modem Card Power Supply Requirements in 21-Card

Enclosure

If you are using more than nine 326X cards in a Modular Nest 21 enclosure, you
must have two power supplies. A third power supply can be added for redundancy.

Advertising