STEP 4: INSTALLING ANTI-TIP DEVICE

Parts Required for Installation of Anti-Tip Device:

PRG304 and PRG36 All Gas Ranges (Figures 9 and 10)

15-10-948 (2 Each)

15-10-910 (1 Each)

15-10-911 (2 Each)

15-10-771 (1 Each)

15-10-916 (4 Each)

15-10-772 (1 Each)

15-10-909 (1 Each)

Mounting Bracket

FIG. 9 Mounting Kit for PRG304 and PRG36

All-Gas Ranges

PRDS304 and PRDS36 Dual
Fuel Ranges (Figure 11)

Thermador Part No. Qty Description

15-10-916

4

Screw, Phillips,#10 x 1-1/2"

15-10-770

1

Anti-Tip Channel, Adjustable,

IMPORTANT INSTALLATION INFORMA-
TION:

The anti-tip bracket may be attached to a
solid wood cabinet having a minimum wall
thickness of 3/4".

The thickness of the wall or floor may
require use of longer screws, available at
your local hardware store.

In all cases, at least two (2) of the bracket
mounting screws must be fastened to solid
wood or metal.

Use appropriate anchors when fastening the
mounting bracket to any material other

Thermador Part No. Qty Description

15-10-916

4

Screw, Phillips,#10 x 1-1/2"

15-10-771

1

Anti-Tip Channel, Adjust
able, PRG

15-10-772

1

Mounting Bracket, PRG

15-10-909

1

Bolt, Hex Head, 1/4"-20 x

1/2"

15-10-910

1

Nut, Hex, 1/4-20

15-10-911

2

Washer, Flat, 1/4-20

15-10-948

2

Screw, Phillips, #10 x 1/2"

1-17/32"

1-9/32"

5-1/2"

This Hole
For Flush
Mount of
PRG36

This Hole
For Flush
Mount of
PRG304

FIG. 10 Adjustable Anti-Tip Channel PRG304

and PRG36 All-Gas Ranges

FIG. 11 Mounting Kit for PRDS304 and PRDS36

Dual Fuel Ranges

15-10-770 (1 Each)

15-10-916 (4 Each)

than hardwood or metal.

Prepare holes at fastener locations as
identified below:

-

For walls, wall studs, or floors composed
of solid wood or metal, drill 1/8" pilot
holes.

-

For walls or floors composed of drywall,
sheet-rock or other soft materials, drill 3/
16" holes to a minimum depth of 1-3/4",
then tap plastic anchors into each of the
holes using a hammer.

-

For walls or floors composed of concrete or
concrete block, drill 3/16" holes to a
minimum depth of 1-3/4", then tap con
crete anchors into each of the holes using
a hammer.

-

For walls or floors having ceramic tile
covering, drill 3/16" holes through the tile
only, then drill into the material behind
the tile as indicated immediately above.

If the range is moved to a new location, the
Anti-Tip Device must be removed and rein-
stalled.